Megatron's New Products / Represented Products   for your attention:

RCD-8
    RCD - DIN-rail mounting Programmable Recyclic Timers
    RCD-8 operate 4 up to 8 loads at recycled mode.
     RCD-16 operate 8 up to 16 loads.
  • Output: 4 / 8 / 16 "Electronic Contacts", 1A / 230 VAC or 24 VDC.
  • Power supply: 110 / 220VAC or 24 VDC
  • Repeatability: +1% under fixed condition.
  • Display: 4/8/16 LED-s indicate active output.
RCD-16
MATP
    Analog to Frequency Converter MATP

    MATP Converts Analog Signals to Pulses 0.01Hz...KHz.
    ( 60 pulses per hour - 0.0166Hz).
    The MATP is used for accumulation A/h or volume units (m3, Galons etc..) by an external counter.
  • Input :  4-20mA / 0-60mV DC, 0-10V DC etc..
  • Outputs :  pulses 24V / O.C. / optocoupler / dry contact.
  • Power supply : 110/220 VAC or 12/24 VDC
  • Compact , DIN rail-mounted enclosure with 12 Pin plug-in connector.
    Two 2 wire Transmitters in one package MTWT-I-D

    MTWT-I-D includes 2 "two wire Isolated Transmitters".
    Convert 2 Electrical input signals into two Galvanic Isolated output signals.
  • Inputs :  4-20mA / 0-10V DC
  • Outputs :   4-20mA passive
  • Power supply : 13 - 30 VDC
  • Zero and Span calibration for each transmitters
  • DIN rail-mounted enclosure
MTWT-I-D
MISCN-D
    Dual Output Transmitter MISCN-D

    Converts electrical input signal to two Galvanic isolated output signals.
  • Input :  4-20 mA ( Rin < 20 Ohm ) or 0-10V.
  • Outputs :  2 Active Outputs 4-20 mA or 0-10V
      or one 4-20 mA and the second 0-10V.
  • Power supply : 24VDC or 12VDC.
  • Zero and Span calibration for each output.
  • Galvanic Isolation between : Input , Outputs and power-supply.
  • Compact , DIN rail-mounted enclosure with 12 Pin plug-in connector.
    MTCT - 3 transmitters (2 wire, Isolated) in one package.
  • Input: AC current up to 10A ( the conductor passes through taroid coil).
  • Accuracy : +1.0%F.S.
  • Output : 4-20mA passive ( 2 wire )

Megatron's New Represented Products   for your attention:

PULSAR

BlackBox
dB Transducers
    BLACKBOX Ultrasonic System for level monitoring and control.
  • Range: Dependent on Transducer. Nominally 0.125m to 40m .
  • Signals are being analysed by Pulsar's amazing DATEM software
  • Power Supply:115/230V AC / 24V DC.
  • BLACKBOX: ( Keyboard and display)
    Model BB130: 2 Relays and 4-20 mA.
    Model BB134 for digital communications Modbus or Profibus.
    Model BB136 has internal Data Logger.
  • Series of dB Transducers are ATEX Zone 1 certified, with the option of Zone 0.

IMP
    IMP - All-in-one self contained Ultrasonic units for level monitoring and control.
  • Ranges: 0.125-3m (IMP 3), 0.3-6m (IMP 6), 0.3-10m (IMP 10).
  • 2 alarm relays.
  • 2 / 3 wire connection , 2-wire I.S.
  • Program by the integral keypad or by using IMPview software.
Ultra 3/5
Ultra Twin

    ULTRA 3 / ULTRA 5   - All-in-one level & Volume Ultrasonic measurement instruments.
  • Ranges: 0.125-40m (depending upon transducer).
  • Output: 3 Relays (ULTRA 3) / 5 Relays (ULTRA 5).
  • Max separation between transducer and controller - 1000m.
  • Display: 6 digits+12 characters text + bargraph with direction indicators.

    ULTRA TWIN - Dual-channel ultrasonic system.
    Each channel can be configur to level-volume monitoring / pump control or as OCM.

  • Ranges: from 70mm to 40m (depending upon transducer).
  • Two displays: each channel has its own display.
  • Outputs: 2 Analogue - isolated 4-20mA / 0-20mA;
    6 Relays (5A/240V); Digital - duplex RS232.
  • Power: 115/230Vac, 10-36Vdc.
BCM SENSOR
Pressure Transducers & Transmitters
Transmitters
  • Technologies: metall-foil strain gauge •  piezo-resistive silicon die  •  ceramic sensor
  • Measuring ranges: 0/10, ..., 0/700  •  -1/0, ..., 0/6  •  0/2,...,0/20 bar
  • Output:4-20 mA / mV / V
Differential Pressure Transmitter
Differential Pres. Transmitter
Measure the differential pressures in mbar scale with high accuracy.
For Differential, Gauge and Absolute Pressure.
AALBORG

RotaMeters (variable area type flowmeters)
  • Single & Multiple Tube Flow Meters;
  • Brass, Stainless and PTFE Flow Merets ets..
  • Flow Meters are installaled vertically in lines Gases or Liquids to be monitored.
Mass Flow Meters and Controllers
  • Flow ranges from 10 sccm to 1000 sL/min N2;
  • Max pressure of 500 psig;
  • 0-5 VDC and 4-20mA Outputs;
  • Built-in tiltable LCD readout.

Vortex Flow Meter
Vortex Inline Flowmeter
  • Fluid types: liquid, Gas, Steam
  • Pipe: 3/4" to 6"
  • Air flow range: 2.2 to 58123 SCFM
  • Outputs: 4-20 mA
Abest
Fixed and Portable Transit Time Ultrasonic Flow Meters.
  • Features:
    • Flow: 0 to 12 metres per second
    • Accuracy: ±0.5% of measured value
    • Pipe Size: 25mm to 5000mm (1 to 200")
Belt-Way Scales
Belt Scales Solids Flow Meters
  • Easy to install
  • NEMA 4x enclosure
  • Self-aligning
  • Power: 120Vac/220Vac/12Vdc/24Vdc.
  • Integrators:
    Belt Way Control
Impact Continuous in-line weighing of dry bulk materials from powders to granules.
Material Flows down a tube and strikes an impact plate that is supported by two single point suspension Load Cells.
LASCAR
Data Loggers

The worlds first range of direct to USB interface data loggers.
This range includes loggers that measure Temperature, Humidity, Voltage or 4-20mA Loop Current.
ELECTRO SENSORS
Industrial Speed and Vibration Monitoring and Motor Controls.
  • Sensors, Switches & Pulse Generators
  • Caunters & Tachometers
  • Vibration Monitors & Tilt Switches
  • Closed Loop Motor Controllers

  10 Mar. 2011